GP1A73A/GP1A73A1
GP1A73A/GP1A73A1
s
Features
1. Compact type
2. TTL compatible owing to OPIC output
3. Snap-in mounting type
4. 3 kinds of mounting plate thickness
(Applicable plate thickness : 1.0, 1.2 and 1.6 mm)
Compact OPIC Photointerrupter
with Connector
s
Outline Dimensions
GP1A73A
( 6.8)
SHARP
JAPAN
(Unit : mm)
8.0
7.8
73
2.3
(Sensor center)
JAPAN AMP made
connector 175487-3
4.7
2-0.5
鹵
0.1
(Slit)
3.2
1
:
V
CC
2
:
V
out
3
:
GND
(Case surface)
13.6
4.3 5.0 4.3
1.6
6.8
鹵
1
7.2
1.1
0.6
0.2
2.3
1.1
1. Copiers
2. Laser beam printers
3. Facsimiles
5.6
s
Applications
5.8
2.4
5.4
6.9
9.9
11.4
2.3
2-0.9
2-0.5 4.0
*
Unspecified tolerances
shall be as follows.
*
( ) : Connector dimensions
for reference
Dimension
d < 5.0
5.0<= d < 15.0
15.0
<=
d
Tolerance
1.2
0.75
14.0
16.8
17.0
鹵
0.15
鹵
0.2
鹵
0.3
GP1A73A1
( 5)
SHARP
JAPAN
8.0
8.0
HIROSE made
connector DF3A-3P-2DSA
4.7
2-0.5
鹵
0.1
(Slit)
3.2
3
:
V
CC
2
:
V
out
1
:
GND
1.6
5.0
鹵
1
5
2.3
(Sensor center)
(Case surface)
13.6
4.3 5.0 4.3
* "OPIC" (Optical IC) is a trademark of the SHARP Corporation.
An OPIC consists of a light-detecting element and signal-processing circuit
integrated onto a single chip.
7.2
s
Absolute Maximum Ratings
Parameter
Supply voltage
Output voltage
Low level output current
Operating temperature
Storage temperature
Symbol
V
CC
V
out
I
OL
T
opr
T
stg
(Ta=25藲C)
Rating
- 0.5 to + 7
- 0.5 to + 7
8
- 20 to + 75
- 30 to + 85
Unit
V
V
mA
藲C
藲C
5.6
73
1.1
0.6
0.2
2.3
1.1
2.4
5.4
6.9
9.9
11.4
2.3
2-0.9
2-0.5 4.0
*1
*2
*3
*3
1.2
0.75
14.0
16.8
17.0
*
Unspecified tolerances
shall be as follows.
*
( ) : Connector dimensions
for reference
Dimension
d < 5.0
5.0<= d < 15.0
15.0
<=
d
Tolerance
*1 Output transistor collector-emitter voltage
*2 Output transistor collector current
*3 The connector should be plugged in/out at normal temperature.
鹵
0.15
鹵
0.2
鹵
0.3
s
Internal Connection Diagram (Both GP1A73A/GP1A73A1)
Constant
voltage circuit
GND
Vout
Connector terminal No.
GP1A73A GP1A73A1
3
:
GND 1
:
GND
2
:
Vout 2
:
Vout
1
:
Vcc
3
:
Vcc
Amp.
Vcc
*
GP1A73A
and
GP1A73A1
are different in the terminal marking number of
connectors from each other due to use of connectors of different manufacturers.
鈥?/div>
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.
鈥?/div>