Relays
Series GD
Force guided relay rated for 6A, 230/240 Vac, 300 Vdc Available
in 4 pole configuration. Polarized DC Drive. See Table 1 for part
numbers.
New Series GD
6A, 230/240VAC, 300VDC
SINGLE THROW FOUR POLE
ELECTRICAL SPECIFICATIONS
GENERAL SPECIFICATIONS
Parameter
Operate Time (See Note 1)
Release Time (See Note 1)
Switching Frequency
Shock (11 msec, See Note 3)
Vibration (10-200 Hz, See Note 3)
Electrical Life
Mechanical Life
Ambient Temperature
Min
Typ
17
7
Max Units
msec
msec
5
10
5
Hz
g
g
Cycles
Cycles
80
o
FEATURES:
鈥?Force Guided Contacts per EN50205:
Consists of at least one NO and one NC
contact mechanically linked. This allows
the contact鈥榮 behavior to be pre-
determined and the user the ability to
monitor the contact.The mechanism
provides true status.
鈥?Dielectric designed for 3-phase systems.
鈥?Contacts are physically linked making it
impossible for a NO and NC to be closed
simultaneously.
鈥?Internal creepage distances and
clearances are designed for Overvoltage
Category III and Degree of Pollution 2 per
IEC 60664.
鈥?Wide range of Contact configurations and
Coil Voltages.
10
5
10
7
-25
C
CONTACT SPECIFICATIONS
Maximum Load Current
1 Contacts
2 Contacts
3 Contacts
Maximum Switching Voltage
6
4.2
3.5
A
A
A
APPROVALS:
CUL: Approved
T脺V / VDE: Pending
230/240 Vac
300
Vdc
Maximum Load Capacity (Resistive)
Maximum Switching Capacity
(Inductive)
Contact Resistance (See Note 2)
Dielectric Test Voltage (O=III, P=2)
Coil to Contact
Contact to Contact
1500/30 VA/W
ACCESSORIES:Contact Factory
AC15-230/240V
DC13-24V
4
2
Arms
Adc
Current regulator unit DIL housing
Current regulator unit SO.8 housing
Removing tool
Socket with soldering pins for PCB mounting
Socket for conventional mounting.
100 mOhm
2500
2000
Vac
Vac
漏 2000 TELEDYNE RELAYS
800-284-7007 鈥?www.teledynerelays.com