鈥?/div>
Datacom (hubs, routers)
POS terminals
Industrial
Cable modems
External disk storage
Medical instrumentation
Computers
Description
The BLP30 Series鈥?economical and compact construction provides single or three-output AC to DC power
conversion to meet the requirements of most commercial and industrial applications.
Single-Output Model Selection
Model
Nominal
Output Voltage
(VDC)
5V
12V
24V
Min-Max Output
Current (Amps),
Convection
0鈥?
0 鈥?2.1
0 鈥?1.0
Min-Max Output
Current (Amps),
1
Forced Air
0鈥?
0 鈥?2.5
0 鈥?1.25
Peak Output
Current
(Amps)
2
7.2
3.0
1.5
Total
Regulation
3
(%)
鹵
2
鹵
2
鹵
2
Ripple &
Noise
4
pk-pk %
1
1
0.6
BLP30-1005G
BLP30-1012G
BLP30-1024G
Triple-Output Model Selection
Model
Nominal
Output Voltage
(VDC)
+5V
BLP30-3000G
+12V
-12V
1
Min-Max Output
Current (Amps),
Convection
0.2 鈥?2.5
0.1 鈥?1.2
0.0 鈥?0.3
Min-Max Output
Current (Amps),
Forced Air
1
0.2 鈥?3.5
0.1 鈥?2.0
0.0 鈥?0.5
Peak Output
Current
(Amps)
2
5
3
1
Total
Regulation
(%)
3
鹵2
鹵5
鹵5
Ripple &
Noise
4
pk-pk %
1%
1%
1%
2
3
4
10 CFM or 260 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm) cross-sectional area with
power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC input to the DC output.
Peak current duration for less than 30 seconds with a max duty cycle of 10%.
At 25
擄C
ambient including voltage set point tolerance, line, and load regulation
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, measured with a twisted pair differentially
across a 10 碌F E-cap and a 0.1 碌F ceramic cap in parallel. The point of measurement is within 1 cm of the output connection.
JUL 05, 2006 revised to DEC 05, 2006
Page 1 of 6
www.power-one.com